Samson RFX Keypad 2190 Manual de usuario

Busca en linea o descarga Manual de usuario para Teclados numéricos Samson RFX Keypad 2190. 2190 RFX Keypad Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 37
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
The Samson RFX is designed to control and monitor the consumption
and inventory balances of automotive fluid products with minimal
installation and programming costs. The wall mounted keypad module
consists of a 12-button keypad, LCD display and integral ticket printer.
The RFX keypad can control up to 48 meters and track 8 different
fluids and tanks. It is capable of sending and receiving data typically
up to 300 feet in a service facility installation. A unique, patented
feature of the control system is that the dispense trigger of the RFX
Meter is locked until authorization from the keypad is received. After
the dispense is completed, the user can top off the dispense and the
actual amount used is sent back to the keypad and this meter returns
to the locked status. Additionally, the meter can be installed on
portable dolly systems offering control and monitoring of often high-
cost lubrication products. Up to 50 operators can be defined with their
own unique PIN number for accessing the system. The system
provides dispense reports by operator, fluid type, meter or tank. This
allows for flexibility in reviewing system activity.
The operator enters his PIN number and selects the hose that the fluid is to be dispensed from.
The operator then enters the required quantity and presses ENTER to confirm. The meter is then
authorized to automatically dispense and shut off when the authorized amount of fluid is
dispensed. The operator may then top off the vehicle for the proper fill, if necessary. The operator
may allow the meter to “time out” or may depress “Reset” which sends all actual dispense data
back to the keypad and puts the meter into a secure “Locked” status until the next authorized
dispense work order is received from the keypad. After each dispense, a transaction ticket is
printed showing the fluid and quantity dispensed along with the operator's name.
Mount the keypad to the wall either inside the shop on a wall facing the shop. In either case
mount the included remote antenna INSIDE the shop up high on the wall with line of sight to all
the meters.
Range is 300 feet unobstructed, be sure to test the keypad/antenna mounting position with a 2188
meter at all positions in the shop, and try to simulate a ‘worst case scenario’ with vehicle
obstructions during testing. Performing this important step will ensure trouble-free service for the
End User and no callbacks for the Installer.
RFX Keypad
Parts and Technical Service guide
Guía de servicio técnico y recambio
Guide d’instructions et pièces de rechange
Ref.:
Model 2190
2190
1
Descri
p
tio
n
/
Descri
p
ción
/
Descri
p
tio
n
E
O
p
eratio
n
/
Modo de em
p
leo
/
Mod
e
d
em
p
lo
i
E
Installation and Confi
g
uratio
n
E
Vista de pagina 0
1 2 3 4 5 6 ... 36 37

Indice de contenidos

Pagina 1

The Samson RFX is designed to control and monitor the consumption and inventory balances of automotive fluid products with minimal installation a

Pagina 2 - Table of Contents

Tank Stock Level No X: --------- Active keys: Numeric keys, , , Use the numeric keys to enter a stock level from 00000.000 to 99999.9

Pagina 3

Tank-Fluid Relationship Screens: The relationship between tank id and fluid type id will be 1:1 (one tank assigned to one fluid type id). For

Pagina 4

Adding and Deleting RF Meters: (Meter and Hose are synonymous) This set of screens allows the Supervisor to add or delete RF Meters from the k

Pagina 5

No Action The relationship between tank and RF Meter will be 1:n (one tank assigned to n meters). Since there will be a relationship between ta

Pagina 6 - 190 - - - - - - - -

Adding and Deleting Operators: • Only an operator with valid PIN can dispense fluid • A Maximum of 50 operators may be active in the system

Pagina 7

Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com

Pagina 8

Configuration Menu: (CNF) The Configuration Menu allows the supervisor to set-up all parameters for the Keypad Operation. The Supervisor is th

Pagina 9 - ,

System Reset: Allows the user to reset all the configuration parameters to default values: System Reset YES / NO Active keys: , , Action:

Pagina 10

Mileage and Registration Information Option: Allows the supervisor to select the storage of vehicle mileage and registration information for ea

Pagina 11

Keypad Timeout Option: • Timeout parameter corresponding to the time it takes to validate after all dispense order data has been entered. If t

Pagina 12

Table of Contents Diagram of RFX Logical Set-up...3 Keyb

Pagina 13

Display Timeout Option: (Do Not Change) • Timeout parameter corresponding to the time for displaying information on the keypad LCD before it is

Pagina 14

Action: • Use scroll key to select the external printer setting • Press Enter key to move to select the external printer setting and Supervis

Pagina 15

Action: Select YES or NO by using the scroll key, then press Enter. The keypad will display the Supervisor Menu. Meter Reset Menu (MET): •

Pagina 16

Report Menu Screens: (REP) The supervisor has the opportunity to print out a variety of reports, if there is an external printer connected to t

Pagina 17

Initialization Report: DD/MMM/YYYY INITIALIZATION REPORT HH:MI TNK PRODUCT LEVEL UNT === ================ ===== ====== 1 Fluid 1

Pagina 18

Configuration Report: DD/MMM/YYYY CONFIGURATION REPORT HH:MI Mileage Type KM Registration Info NO Mileage Info NO Inter

Pagina 19

Communications Report: DD/MMM/YYYY COMMUNICATION REPORT HH:MI ADDR ID STA ====== ==== === 0.000.000.101 1 inactive 0.000.000.137 2 inactiv

Pagina 20

Dispense Order Reports: Select Report INI CNF COM WO Active keys: , , Action: • Scroll to WO and press Enter key • Enter key with no en

Pagina 21

Product Report (PRO): DD/MMM/YYYY STATISTICAL REPORT BY PRODUCT HH:MI PRODUCT USER QTY ================ ==============

Pagina 22

Tank Report (TNK): DD/MMM/YYYY STATISTICAL REPORT TANK LEVEL HH:MI TNK PRODUCT LEVEL UNT === ================ ===== ======= 1 5W30

Pagina 23 - INI CNF MET WO

PICTORAL DIAGRAM OF RFX LOGICAL SET-UP Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com

Pagina 24

Internal Printer Reports: FLU: Prints all fluids created in the system HDS: Prints all hose numbers with meter serial numbers TNK: Prints

Pagina 25

Fluid Type Definitions Fluid id Name 1 2 3 4 5 6 7 8 Maximum Fluid types is 8 The Fluid name can be 16 characters in le

Pagina 26

Tank Definitions Tank id Tank Level Tank Capacity 1 2 3 4 5 6 7 8 Maximum of 8 Tanks The Tank Capacity

Pagina 27

Hose/Meter Definitions Hose/Meter id Address Number x.xxx.xxx.xxx 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Pagina 28

Hose/Meter Definitions Hose/Meter id Address Number x.xxx.xxx.xxx 25 26 27 28 29 30 31 32 33 34 35 36 37 38

Pagina 29

User Definitions User id User Name Pin id 1 Reserved Supervisor0000 2 3 4 5 6 7 8 9 10 11 12

Pagina 30

User Definitions User id User Name Pin id 26 27 28 29 30 31 32 33 34 35 36 37 38 39

Pagina 31 - Maximum Fluid types is 8

Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com

Pagina 32 - Maximum of 8 Tanks

Keyboard Description: FCC ID: GIF-RFKEYPAD FCC CERTIFIED, PART 15, SUBPART C This device complies with Part 15 of the FCC Rules.

Pagina 33 - Maximum of 48 Hose/Meters

Default Screens: • The Personal Identification Number (PIN) number is 4 numeric digits • 1 supervisor account • Maximum of 50 operators •

Pagina 34

Management Menu: The management menu displays after entering the supervisor PIN Number Select INI CNF MET REP190 - - - - - - - - -

Pagina 35

Initialization Menu: Flow Chart aThe parameter changes will affect all data in memory (example: if we change the quantity unit from liters to

Pagina 36 - Maximum of 50 users

Initialization Menu Screens (INI): • System date and time are initially blank • System time is in military standard • System date is in fo

Pagina 37

Tank Initialization: The tank screens are used to set up the tanks in the system. Each tank is assigned a number and a starting quantity leve

Comentarios a estos manuales

Sin comentarios